20 | Rinnai Heating Specication Guide 02-13
Super Rays
Rinnai Super Ray codes
Gas Type Indoor Super Ray 16 Indoor Super Ray 24 Indoor Super Ray 40 Outdoor Super Ray
Electronic
Manual
Electronic
Manual
Electronic
Manual Manual only
NG WEA16N WMA16N WEA24N WMA24N WEA40N WMA40N ODHRAD3MN
LPG WEA16L WMA16L WEA24L WMA24L WEA40L WMA40L ODHRAD3ML
Electronic/manual refers to how the unit is switched on. Electronic uses a switch and manual uses a pull-cord.
Description
Rinnais infra-red wall-mounted, semi-industrial Super Ray heaters provide efficient spot heating.
Unaffected by external air currents, the heat is channelled to specific areas.
Suitability: Indoor Super Rays
Commercial and industrial use only. The heaters can be used for either spot or total heating, depending
on the requirement of the application. They are not suitable for indoor domestic use.
• WEA (electronic models) are not suitable for outdoor use
• WMA models can be installed in covered, sheltered outdoor areas, but must be protected against
direct exposure to wind, rain, and salt spray
Suitability: Outdoor Super Ray
• Domestic use, outdoor onlyrefer appendix 4 (p. 34) for the definition of an outdoor area
• Commercial use, outdoor and indoor
1
(appliance must not be used in a room smaller than 120 m
3
)
Not recommended for locations directly near the sea.
1
For indoor use, these appliances must be used in a well ventilated area. Ventilation requirements must comply with AS/NZS 5601.1.
Positioning considerations
Super Ray heaters direct their heat via infra-red rays which discharge the heat energy upon striking
a surface. They do not pass through solid materials. From a heating and a safety point of view, when
installing the units, obstructions to the path of the rays must be taken into consideration. Obstructions
in the path of the rays should be avoided where possible.
Materials stored near the heater must be at a safe
distance as the infra-red rays heat solid objects
quicklyrefer p. 22 for clearance information.
For safe operation the mounting bracket of the
Super Ray is designed so the heater is mounted at an
angle. The bracket must not be altered/adjusted, or
another bracket substituted to alter this angle.
Super Ray is mounted correctly with
the supplied bracket and bracket
installed as per instructions.
Super Ray is mounted incorrectly and
bracket has been modified so the
heater angles directly downwards.
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 35 36

Comentarios a estos manuales

Sin comentarios