18 | Rinnai Heating Specication Guide 02-13
Dynamo RCE471 Avenger RCE671
Colour White with grey louvres White with grey louvres
Efficiency* 100% 100%
Energy star rating 5.8 star energy equivalent 5.8 star energy equivalent
Gas connection ” MI BSP into 1.5 metre flexible gas hose
with bayonet connection
” MI BSP into 1.5 metre flexible gas hose
with bayonet connection
Heating area:
- warm zone
- medium zone
- cool zone
Minimum room size
51.5 m²
45 m²
38 m²
37.5 m
3
95 m²
80 m²
70 m²
62.5 m
3
Input 6-15 MJ/h 8.5-25 MJ/h
Output** 1.7-4.2 kW 2.4-6.2 kW
Noise level 40 dB(A) 41 dB(A)
Power consumption 16-21 W, standby < 0.8 W 16.5-27.5 W, standby < 0.8 W
Power cord Located lower right hand side of rear panel Located lower right hand side of rear panel
Remote control Yes Yes
Temperature range 16-26 °C 16-26 °C
Weight 10 kg 12 kg
Additional features Common to both models: Preheat function, dual timers, manual control, electronic ignition,
economy mode, air filter, overheat safety device, and child lock.
Servicing For reliable operation Rinnai Portable Convectors should be checked by a licensed
tradesperson every two years. If located in a particularly dusty environment or subject to
excess lint, for example dog hair or where there are newly laid carpets, then annual servicing
would be beneficial.
* Unflued appliance ** Will vary depending on gas type
Dimensions - Dynamo Dimensions - Avenger
Control panel and remote for both models
Portable Convector specication summary
244 mm
126 mm
487 mm
492 mm
ON
OF F
239 mm
202 mm
610 mm
482 mm
Comentarios a estos manuales